Image Segmentation
Transformers
ONNX
English
medical
ultrasound
obstetrics
segmentation
classification
regression
multi-task
intrapartum
labor-monitoring
medsiglip
siglip
clinical-ai
Instructions to use samwell/laborview-medsiglip with libraries, inference providers, notebooks, and local apps. Follow these links to get started.
- Libraries
- Transformers
How to use samwell/laborview-medsiglip with Transformers:
# Use a pipeline as a high-level helper from transformers import pipeline pipe = pipeline("image-segmentation", model="samwell/laborview-medsiglip")# pip install -U transformers accelerate # Load model directly from transformers import AutoModel model = AutoModel.from_pretrained("samwell/laborview-medsiglip", device_map="auto") - Notebooks
- Google Colab
- Kaggle
|
Download README.md from samwell/laborview-medsiglip: direct link, hf CLI and curl.
- Browser
- Download file 9.91 kB
-
https://huggingface.co/samwell/laborview-medsiglip/resolve/main/README.md
- Command line
-
hf download hf://samwell/laborview-medsiglip/README.md
-
curl -L -o README.md https://huggingface.co/samwell/laborview-medsiglip/resolve/main/README.md
9.91 kB
metadata
license: apache-2.0
library_name: transformers
pipeline_tag: image-segmentation
tags:
- medical
- ultrasound
- obstetrics
- segmentation
- classification
- regression
- multi-task
- intrapartum
- labor-monitoring
- onnx
- medsiglip
- siglip
- clinical-ai
datasets:
- custom
language:
- en
metrics:
- iou
- dice
- accuracy
- mae
base_model:
- google/medsiglip-448
LaborView MedSigLIP
Multi-task AI model for intrapartum ultrasound analysis during labor
Model Description
LaborView MedSigLIP is a multi-task vision model for comprehensive analysis of transperineal ultrasound during labor. Unlike single-task segmentation models, it simultaneously performs:
| Task | Output | Description |
|---|---|---|
| Segmentation | 3-class mask (HΓW) | Pubic symphysis, fetal head, background |
| Classification | 6-class logits | Standard ultrasound plane detection |
| Regression | 2 values | Direct AoP and HSD predictions |
Why Multi-Task?
- Efficiency: Single forward pass for all outputs
- Shared Features: Tasks benefit from shared visual representations
- Clinical Workflow: Provides complete assessment, not just masks
- Uncertainty Weighting: Learned task weights balance losses automatically
Architecture
Input Image (448Γ448 RGB)
β
βΌ
βββββββββββββββββββββββββββ
β MedSigLIP β Vision Encoder
β (SigLIP-SO400M) β 1152-dim features
β google/medsiglip-448 β
βββββββββββββ¬ββββββββββββββ
β
ββββββββ΄βββββββ
βΌ βΌ
βββββββββββ βββββββββββββββ
β Pooled β β Sequence β
βFeatures β β Features β
β (1152) β β(NΓ1152) β
ββββββ¬βββββ ββββββββ¬βββββββ
β β
βΌ βΌ
βββββββββββ βββββββββββββββ
βProjectorβ β Seg Decoder β
β (512) β β (FPN-style) β
ββββββ¬βββββ ββββββββ¬βββββββ
β β
ββββ΄βββ β
βΌ βΌ βΌ
ββββββββββββ ββββββββββββ
βCls ββReg β β Seg Mask β
βHeadββHeadβ β(3ΓHΓW) β
ββββββββββββ ββββββββββββ
β β β
βΌ βΌ βΌ
Plane AoP, Symphysis,
Logits HSD Head Masks
(6) (2) (3Γ448Γ448)
Model Outputs
@dataclass
class LaborViewOutput:
plane_logits: Tensor # (B, 6) - Standard plane classification
seg_masks: Tensor # (B, 3, H, W) - Segmentation masks
labor_params: Tensor # (B, 2) - [AoP degrees, HSD pixels]
Training
- Dataset: HAI-DEF Challenge - Transperineal ultrasound with expert annotations
- Base Model:
google/medsiglip-448(1152-dim, ~400M encoder params) - Multi-Task Loss: Uncertainty-weighted combination (Kendall et al.)
- Segmentation: Dice + Cross-Entropy
- Classification: Cross-Entropy
- Regression: Smooth L1
- Training Strategy:
- Epochs 1-3: Frozen encoder (head warmup)
- Epochs 4+: Full fine-tuning with gradient checkpointing
- OneCycleLR scheduler, 5e-5 max LR
- Augmentation: HorizontalFlip, RandomBrightnessContrast, GaussNoise, ShiftScaleRotate
Intended Use
Primary Use Cases
- Automated Labor Assessment: Real-time analysis of labor progress
- Clinical Decision Support: AI-assisted measurements for clinicians
- Training/Education: Teaching tool for ultrasound interpretation
- Research: Standardized measurement extraction for studies
Output Interpretation
Segmentation Classes
| Class | ID | Color | Anatomical Structure |
|---|---|---|---|
| Background | 0 | Transparent | Non-anatomical |
| Pubic Symphysis | 1 | Cyan | Pelvic joint landmark |
| Fetal Head | 2 | Magenta | Presenting fetal part |
Plane Classification
| Class | Description |
|---|---|
| 0 | Transperineal (standard) |
| 1 | Transabdominal |
| 2 | Oblique |
| 3 | Sagittal |
| 4 | Axial |
| 5 | Other/Non-standard |
Labor Parameters
| Parameter | Range | Clinical Meaning |
|---|---|---|
| AoP (Angle of Progression) | 90-160Β° | Head descent angle |
| HSD (Head-Symphysis Distance) | 0-100+ px | Head-to-pelvis distance |
AoP Interpretation:
| AoP | Stage | Status |
|---|---|---|
| < 110Β° | Early labor | Head not engaged |
| 110-120Β° | Active labor | Descending |
| 120-140Β° | Advanced | Good progress |
| > 140Β° | Late labor | Delivery imminent |
Users
- Obstetric ultrasound software developers
- Medical device manufacturers
- Clinical researchers in maternal-fetal medicine
- Healthcare AI developers
- Medical education platforms
Out of Scope
- Direct clinical diagnosis without physician oversight
- Replacement for clinical judgment
- Non-transperineal ultrasound views
- Fetal anomaly or malformation detection
- Gestational age estimation
How to Use
PyTorch Inference
import torch
from model import LaborViewMedSigLIP
from config import Config
# Load model
config = Config()
model = LaborViewMedSigLIP(config)
checkpoint = torch.load("best.pt", map_location="cpu")
model.load_state_dict(checkpoint["model_state_dict"])
model.eval()
# Inference
image = preprocess_image("ultrasound.png") # (1, 3, 448, 448)
with torch.no_grad():
plane_logits, seg_masks = model(image)
# Parse outputs
plane_class = plane_logits.argmax(dim=1).item()
seg_mask = seg_masks.argmax(dim=1)[0].numpy()
ONNX Runtime
import onnxruntime as ort
import numpy as np
from PIL import Image
# Load model
session = ort.InferenceSession("laborview.onnx")
# Preprocess
image = Image.open("ultrasound.png").convert("RGB").resize((448, 448))
img = np.array(image).astype(np.float32) / 255.0
img = (img - 0.5) / 0.5 # MedSigLIP normalization [-1, 1]
img = img.transpose(2, 0, 1)[np.newaxis, ...]
# Run multi-task inference
plane_logits, seg_masks, labor_params = session.run(None, {"image": img})
# Parse all outputs
plane_class = np.argmax(plane_logits, axis=1)[0]
seg_mask = np.argmax(seg_masks, axis=1)[0]
aop, hsd = labor_params[0]
print(f"Plane: {['transperineal','transabdominal','oblique','sagittal','axial','other'][plane_class]}")
print(f"AoP: {aop:.1f}Β°, HSD: {hsd:.1f}px")
Clinical Metrics from Segmentation
from clinical_metrics import compute_all_metrics
# Compute comprehensive clinical assessment
metrics = compute_all_metrics(
segmentation_mask=seg_mask,
symphysis_class=1,
head_class=2
)
print(f"Angle of Progression: {metrics.aop:.1f}Β°")
print(f" β {metrics.aop_interpretation}")
print(f"Head-Symphysis Distance: {metrics.hsd:.1f} px")
print(f" β {metrics.hsd_interpretation}")
print(f"Head Circumference: {metrics.head_circumference:.0f} px")
print(f"Head Area: {metrics.head_area:.0f} pxΒ²")
print(f"Segmentation Quality: {metrics.segmentation_quality} ({metrics.confidence:.0%})")
print(f"Labor Progress: {metrics.labor_progress.upper()}")
print(f"Recommendation: {metrics.recommendation}")
Model Files
| File | Description | Size |
|---|---|---|
best.pt |
Best validation checkpoint | ~1.6 GB |
final.pt |
Final epoch checkpoint | ~1.6 GB |
laborview.onnx |
ONNX export (all heads) | ~1.6 GB |
config.json |
Model configuration | 1 KB |
Performance
Multi-Task Metrics
| Task | Metric | Value |
|---|---|---|
| Segmentation | Mean IoU | TBD |
| Segmentation | Dice Score | TBD |
| Classification | Accuracy | TBD |
| Regression (AoP) | MAE | TBD |
| Regression (HSD) | MAE | TBD |
Inference Speed
| Platform | Resolution | Latency |
|---|---|---|
| NVIDIA A100 | 448Γ448 | ~15ms |
| Apple M1 | 448Γ448 | ~50ms |
| CPU (8 cores) | 448Γ448 | ~200ms |
Limitations
- Training Data: Single dataset/protocol; may need fine-tuning for different equipment
- Population Coverage: May not generalize to all patient demographics
- Image Quality Dependence: Degrades with poor quality, shadows, artifacts
- Anatomical Variations: May struggle with unusual presentations
- Calibration Required: Pixel values need device-specific mm conversion
- Regression vs Computed: Direct AoP/HSD predictions may differ from geometry-computed values
Ethical Considerations
- Decision Support Only: Not a replacement for clinical judgment
- Validation Required: Must validate on local populations before deployment
- Bias Monitoring: Monitor performance across demographic groups
- Regulatory Compliance: FDA/CE approval required for clinical use
- Transparency: Always disclose AI assistance to patients
Citation
@software{laborview_medsiglip_2024,
title = {LaborView MedSigLIP: Multi-Task AI for Intrapartum Ultrasound},
author = {Samuel},
year = {2024},
url = {https://huggingface.co/samwell/laborview-medsiglip},
note = {Multi-task model: segmentation + classification + regression}
}
Related Resources
- laborview-ultrasound - Edge-optimized variant (~21MB)
- Demo Space - Try online
- HAI-DEF Challenge - Dataset and competition
- MedSigLIP - Base encoder
License